Donor Unit | Remote Unit | ||
Working Frequency (customizable) | Uplink (MHz) | 450~457.5 / 824~849 / 1850~1910 | |
Downlink (MHz) | 460~467.5 / 869~894 / 1930~1990 | ||
Link Frequency | Customizable | ||
Transmission Distance | ≤ 20km | ||
No. of Channels (for channel shift) | 1 or 2 | ||
Frequency Error | ≤ 0.05ppm | ||
Max. Output Power (customizable) | Uplink | Cable-Access: ≥ 0dBm Wireless-Access: ≥ 30dBm |
≥ 33dBm |
Downlink | 40dBm | 43dBm | |
Max. Input Level (Non-Destructive) | ≥ -10dBm | ||
Max. Gain | Cable-Access: ≥ 45dB Wireless-Access: ≥ 85dB |
≥ 90dB | |
Gain Adjustment Range | 1~31dB @ step of 1dB | ||
Voltage Standing Wave Ratio (VSWR) | < 1.5 | ||
Noise Figure | < 5dB (only for uplink) | ||
Spurious Emission | Within working band | ≤ -15dBm/30kHz | |
Out of working band (Δf > 2.5MHz) |
30MHz~1GHz: ≤ -36dBm/100kHz | ||
Third-Order Intermodulation | ≤ -15dBm/30kHz | ||
In-Band Ripple | ≤ 3dB | ||
System Delay | ≤ 10μSec | ||
I/O Impedance | 50Ω | ||
RF Connector | N-Type (Female) / changeable / bottom of casing | ||
Temperature Range | Operation: -25°C ~ +55°C / Storage: -30°C ~ +60°C | ||
Relative Humidity Range | ≤ 95% (non condensing) | ||
Power Supply (customizable) | DC -48V / AC 220V, 50/60Hz / AC 110V, 50/60Hz | ||
Backup Power Supply (optional) | 4 hours | ||
Casing Level | IP65 | ||
Dimensions | 428mm x 328mm x 220mm | ||
Weight | 25kg | 30kg | |
NMS Monitoring Function (optional) | Real-time alarm for door status, temperature, power supply, LNA, VSWR, self-oscillation, etc. Remote control such as turn on/off, increasing/decreasing output power, etc. Real-time status for output/input power, UL/DL gain, all status of repeater etc. |
To expand signal coverage or fill the signal blind area where the signal is weak or unavailable.
Outdoor: Airports, tourism regions, golf courses, tunnels, factories, mining districts, villages, …II.Recommended Environmental Requirements:
1.Installation area non-corrosive gases and fumes, Electromagnetic interference field strength ≤140dBμV/m(0.01MHz~110000MHz).
2.Mounting height should facilitate RF cable routing, cooling, safety, and maintenance.
3.Should provide a set of independent and stable 150VAC~290VAC(Nominal 220V/50Hz)AC Power. It must not be shared with other high-power appliances telecommunications equipment.
4.Lightning protection devices must be installed in the building, and it should have sufficient strength and stability.
5.There are grounding bar in the vicinity.
III.Installation Tools
Installation tool to use: Electric impact drill, iron hammer, pulleys, ropes, belts, helmets, ladders, screwdriver, hacksaw, knife, pliers, wrenches, compass, measuring tape, tweezers, electric iron, portable PC, 30dB directional coupler, spectrum analyzers, VSWR tester.
IV.Repeater installation
It can be a holding pole or wall mounting way. It should be installed in a ventilated place, vertically on a wall or mast to ensure good heat dissipation, if hanging on the wall, the upper part of the equipment to be considered more than 50cm from the ceiling, the lower part of the equipment needs more than 100cm from the floor.
V.Safety Instruction
V.I.Antenna and Feeder Installation and Precautions
1.Installation of antenna systems requires experienced professionals to complete.
2.You can not install an antenna near power lines, which may be life-threatening.
3.All exposed joints must use self-adhesive waterproof tape and electrical insulation tape seal securely.
VII.Connect the Ground and Power Supply
1. Equipment Grounding
The equipment must be well grounded, there is a copper on the repeater wall chassis ground, use 4mm2 or thicker copper wire close to the ground. Grounding wire should be as short as possible. When installed, the equipment grounding wire should be connect to the integrated grounding bar. Grounding resistance of requirements bar may be≤ 5Ω, ground connector require preservative treatment.
2. Connect the Power
Connect 220V/50Hz AC power to the equipment power port terminal blocks, power line use 2mm2 cables, length less than 30m.
For standby power requirement, the power must go through UPS, and then connect the UPS to the repeater power port terminal blocks.
*More Details please CLICK it!
More Mobile phone signal booster please CLICK it!
Q1.Payment Method
T/T, Western Union, Paypal, and Credit Card are available,
and we suggest paying by Alibaba Trade Assurance, the most favor, and security method.
*Other methods please Contact us with more details.
Q2.Delivery Date&Lead Time
Quantity | Lead time | Delivery to American/Middle East/Asia/Europe |
<20 pcs | 3-5 business days | 3-7 business days by DHL 5-7 business days by FedEx/UPS |
20-100 pcs | 7-15 business days | |
>100 pcs | 15-24 business days |
Q3. Can I customize frequencies?
Yes, we can customize 2G/3G/4G,GSM850/CDMA450,GSM900,AWS1700,DCS1800,PCS1900,WCDMA2100,LTE700/800/2600,etc.
Q4. What should I do if I don't know about frequency in my country?
Please feel free to Contact us with your inquiry, we will find the frequency you need and address your problems.
360° Full View of Factory Evaluation
Frequency | 2G,3G,4G |
Multi-band | 1-5 Bands |
Output Power | 17dBm-43dBm |
Colors | Accept Customized |
Logo | Accept Customized |
*More Details please CLICK it to contact us!