Customization: | Available |
---|---|
Type: | Signal Repeater |
Transmission Medium: | Wireless |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description:
3G Variable Repeater enable to amplify only the targeted operator's signals and reject all the others effectively, it is, therefore, an optimal solution for the people who want to select the certain signal among different operators.
23dBm Single Band Variable Band Repeater allow small to medium size indoor areas have reliable radio communications for first responders. Automatic gain control allows stable output power even when the handheld is close to the repeater, which protects the donor site from interruption. The unit is housed by a compact and light alumina casting enclosure.
The built-in external LCD accessible from the bottom of the enclosure allow the uplink and down link gains, Output Powers, Alarms and so on be configured and optimized easily on site without additional tool. Signal strength indicator helps find donor signal source and set up the system in the field without additional equipment.
Features:
1. Uplink/downlink frequency can be adjusted.
2. Built-in Saw filter provides high out of band rejection
3. Built-in switches and signal strength indicator allow find donor signal source and set up the system on site without additional equipment
4. External 100-240VAC universal power supply
5. Indoor wall mount
6. Heatsink convection cooling and low power consumption
7. Built-in ALC provides stable output power even when the handheld is close to the repeater to minimize the interference to the donor site
Parts Check List
Please make sure the following items are included in the box delivered to you. If any item is missing, contact your sales representative.
Table.1 Parts check list
Item |
Quantity |
The Repeater, |
1 |
External Power Adaptor |
1 |
M6x40mm Screw with wallboard anchor |
4 |
Customer Manual* |
1 |
* Factory may choose to ship the product along with a hardcopy of this manual, or make it available electronically through website download or email.
Data Sheet
Items | Uplink | Downlink | |
Frequency Range | 1920 - 1980MHz | 2110- 2170MHz | |
Variable Bandwidth | 0.2-20 MHz | 0.2-20MHz | |
Frequency Adjustment Step | 100KHz | 100KHz | |
Output Power | 20±2dBm | 23±2dBm | |
Gain | 70±3dB | 75±3dB | |
Ripple | ≤2dB | ≤2dB | |
VSWR | ≤2 | ≤2 | |
Max. Input Power Without Damage | -10dBm | -10dBm | |
ATT step of 1dB | 1 ~ 10dB | ∣△∣≤1dB | ∣△∣≤1dB |
10 ~ 20dB | ∣△∣≤1dB | ∣△∣≤1dB | |
20 ~ 25dB | ∣△∣≤1.5dB | ∣△∣≤1.5dB | |
ALC Active 10dB | ∣△∣≤2dB | ∣△∣≤2dB | |
Intermodulation Products | ≤ -45dBc | ≤ -45dBc | |
Spurious Emission | 9KHz~1GHz | ≤ -36dBm | ≤ -36dBm |
1GHz~12.75GHz | ≤ -30dBm | ≤ -30dBm | |
Noise Figure @ max. gain | ≤ 8dB | ≤ 8dB | |
Time Delay | ≤ 5μs | ≤ 5μs | |
Alarm | broken | No Light | |
self-excitation | Red | ||
Run | normal | Green | |
self-excitation | Red | ||
Power Supply | AC100V ~ 240V | ||
Power Consumption | ≤100W | ||
Dimensions | 400mmx155mmx45mm | ||
Weight | 2.5kg | ||
RF Connector | N-Female | ||
Environment Conditions | IP40 | ||
Humidity | < 90% | ||
Operating Temperature | -20ºC~+55ºC |
LED Display Panel of Operations Guide.
Display Details:
Working Frequency Range |
Output Power |
Gain |
Alarm item |
Operating Mode : Automatic or manual |
Plug in the AC 220V, User can see "Movable Band Repeater
WCDMA System", Note: can customize Company Logo or Other words.
Click "OK", to enter the Main Menu.
Click "+" or "-", cursor appear,to choose different function.
click "M" back to Main Menu.
2. Click "OUTPUT POWER", click "OK", real-time inquiry Uplink power and downlink power, only for checking, NO setting. click "M" back to Main Menu.
When the display power is below or above standard, Displayed as "---".
3. Click "GAIN", click "OK", real-time inquiry Uplink gain and downlink gain, click "+" or "-",then setting gain which you want. click "OK" finish .
click "M" back to Main Menu.
4. Click "ALARM ITEMS", click "OK", real-time inquiry Uplink PLL, Downlink PLL,
Downlink output power, AGC, Temperature.
only for checking, NO setting. click "M" back to Main Menu.